Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 219
Filtrar
1.
J Adhes Dent ; 26(1): 103-116, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38602234

RESUMO

PURPOSE: To investigate the antibacterial effects of Terminalia catappa Linn (TCL) leaf extracts at different concentrations and the effects of these extracts used as primers on the long-term adhesive properties of two universal adhesives. MATERIALS AND METHODS: After extract preparation, the antimicrobial and antibacterial activities of TCL against Streptococcus mutans (UA 159) were assessed in microdilution assays to provide the minimal inhibitory concentration (MIC) and minimal bactericidal concentration (MBC). Additionally, to provide quantitative data on the ability of TCL extract to reduce cell viability, colony forming units (CFU) were counted. To examine adhesive properties, 288 human molars were randomly assigned to 32 experimental conditions (n = 9) according to the following variables: (1) treatment agent: negative control (untreated surface), and primers at concentrations of 1xMIC, 5xMIC, and 10xMIC; (2) adhesives: Scotchbond Universal (SBU) and Futurabond Universal (FBU); (3) adhesive strategy: etch-and-rinse (ER) or self-etch (SE); and (4) storage time: 24 h or after 2 years. Primers were applied for 60 s, upon which the teeth were incrementally restored and sectioned into adhesive-dentin bonded sticks. These were tested for microtensile bond strength (µTBS) and nanoleakage (NL) after 24-h and 2-year water storage, as well as in-situ degree of conversion (DC) at 24 h. The chemical profile of the hybrid layer was determined via micro-Raman spectroscopy. Biofilm assay data were analyzed using the Kruskal-Wallis test; the pH of culture media and the chemical profile were analyzed by one-way ANOVA. The adhesive properties (µTBS, NL, DC) were evaluated using a four-way ANOVA and Tukey's test. Significance was set at 5%. RESULTS: Similar values of MIC and MBC were observed (2 mg/ml), showing bactericidal potential. CFU analysis demonstrated that concentrations of 5xMIC and 10xMIC significantly inhibited biofilm formation (p < 0.001). The application of the TCL primer at all concentrations significantly increased the immediate µTBS and DC, and decreased the immediate NL values when compared to the control group (p < 0.05), regardless of the adhesive and adhesive strategies. Despite an increase in the NL values for all groups after 2 years (p > 0.05), in groups where the TCL primer was applied, the µTBS remained constant after 2 years for both adhesives, while a decrease in the µTBS was observed in the control groups (p < 0.05). Usually, 10xMIC showed better results than 1xMIC and 5xMIC (p < 0.05). The application of TCL promoted cross-linking; cross-linking rates increased proportionally to the concentration of TCL (p < 0.05). CONCLUSION: Primers containing TCL promoted bactericidal and bacteriostatic action, as well as cross-linking with dentin, while maintaining the adhesive properties of the adhesive-dentin interface after 2 years of water storage.


Assuntos
Colagem Dentária , Terminalia , Humanos , Cimentos Dentários/farmacologia , Cimentos Dentários/química , Adesivos Dentinários/farmacologia , Adesivos Dentinários/química , Resinas Compostas/química , Dentina , Resistência à Tração , Cimentos de Resina/farmacologia , Cimentos de Resina/química , Água/química , Antibacterianos/farmacologia , Teste de Materiais
2.
J Dent ; 144: 104951, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38508441

RESUMO

OBJECTIVES: This study evaluated the efficacy of simulated brushing with toothpastes containing different concentrations of hydrogen peroxide (HP) in pulp chamber penetration and color change. Also, physical-chemical properties (concentration, pH and viscosity) were evaluated. METHODS: Forty-nine premolars were divided into seven groups (n = 7): untreated (control); whitening gel (White Class 6 %, 6 %BG) with one 90  min application (6 %BG 90  min) and 14 applications of 90  min (6 %BG 14×90 min); toothpastes (Colgate Luminous White Glow 3 %, 3 %TP; Crest 3D White Brilliance 4 %, 4 %TP; Colgate Optic White Pro-Series 5 %, 5 %TP) and 6 %BG toothbrushing for 14 applications of 90 s. HP penetration into the pulp chamber was measured through UV-Vis spectrophotometry and color change with a spectrophotometer (ΔEab, ΔE00, and ΔWID). Initial concentration, pH, and viscosity were measured through Titration, Digital pH-meter, and Rheometer, respectively. Statistical analysis used one-way ANOVA and Tukey's test (α = 0.05). RESULTS: 6 %BG (14×90 min) and 4 %TP groups showed acidic pH and higher concentrations of HP in the pulp chamber compared to the other groups (p < 0.05). On the other side, 3 %TP and 5 %TP groups showed alkaline pH, higher viscosity between the toothpastes and lower HP penetration (p < 0.05). The 6 %BG AH (14×90 min) group exhibited the most significant color change (ΔEab, ΔE00, and ΔWID) (p < 0.05). CONCLUSIONS: Brushing with whitening toothpaste with an acidic pH leads to greater HP penetration into pulp chamber; but, even when a high concentrated HP whitening toothpaste was used, a lower whitening effect was observed when compared to a two-week at-home bleaching. CLINICAL SIGNIFICANCE: Whitening toothpastes containing up to 5 % HP produced lower whitening effect than two-week at-home bleaching. Additionally, HP was detected within the pulp chamber which can potentially impact in tooth sensitivity.

3.
Clin Oral Investig ; 28(4): 224, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38509406

RESUMO

OBJECTIVES: To evaluate the bleaching efficacy and permeability of hydrogen peroxide (HP) in the pulp chamber of human teeth bleached with lower concentrations of carbamide peroxide gel (4%, 5% and 7% CP). MATERIALS AND METHODS: Bleaching gels with lower concentrations were formulated and a commercial standard gel, 10% CP, was used as a reference. Fifty-six human premolars were randomly divided into four groups. Applications of the bleaching gel were made for 3 h for 21 days. The bleaching efficacy was evaluated by digital spectrophotometry on 1, 7, 14 and 21 days, with analysis in the ∆Eab, ∆E00 and WID color spaces. The concentration of HP in the pulp chamber was measured in the same periods by UV-Vis spectrophotometry (µg/mL). Two-way repeated analysis of variance (ANOVA) examined bleaching efficacy and HP permeability, followed by Tukey's post-hoc test (α = 0.05). RESULTS: All groups showed significant color changes, with no statistical differences after the second and third week of bleaching (p > 0.05). The 'time' factor was statistically different (p < 0.05), increasing the bleaching efficacy throughout the treatment. The 4% CP group had lower HP levels in the pulp chamber (p < 0.05). CONCLUSIONS: The results seem promising, revealing that low concentration gels are as effective as 10% CP with the benefit of reducing the amount of HP in the pulp chamber. CLINICAL RELEVANCE: Low concentration 4% PC and 5% PC maintains bleaching efficacy, reduces the penetration of HP peroxide into the pulp chamber, and may reduce tooth sensitivity.


Assuntos
Clareadores Dentários , Clareamento Dental , Humanos , Peróxido de Carbamida , Cavidade Pulpar , Clareadores Dentários/farmacologia , Peróxido de Hidrogênio , Clareamento Dental/métodos , Ácido Hipocloroso , Géis , Ureia/farmacologia , Peróxidos/farmacologia
4.
J Esthet Restor Dent ; 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475979

RESUMO

OBJECTIVES: Evaluate the bleaching efficacy (BE) and tooth sensitivity (TS) of in-office bleaching using different application tips. METHODS: Forty-eight participants were selected (split-mouth), one to receive bleaching with an attached brush tip and one with a conventional tip. The procedure was performed with Whiteness Automixx Plus 35%. The BE was evaluated at the beginning, weekly, one and 12 months post-bleaching with a Vita Easyshade spectrophotometer (ΔE*ab , ΔE00 , and WID ) and with Vita classical A1-D4 and Vita Bleachedguide shade guides units (ΔSGU). Absolute risk and intensity of TS were recorded using the Visual Analogue Scale. The equivalence of BE was analyzed using the two one-sided t-tests for paired samples. The absolute risk of TS was evaluated using the McNemar test, and the TS intensity was measured with the paired t test (α = 0.05). RESULTS: The equivalence of BE was observed for both groups in all color evaluations (p > 0.05). A lower absolute risk and intensity of TS were observed for the attached brush tip when compared with the conventional tip (p < 0.003 and p < 0.0001). CONCLUSION: Using an attached brush tip showed the same BE as a conventional tip. However, for the attached brush tip, there was a reduction in TS. CLINICAL SIGNIFICANCE: The applicator-attached brush tip is recommended for in-office dental bleaching, because of the possible reduction in risk and intensity of TS.

5.
J Dent ; 144: 104930, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38471581

RESUMO

OBJECTIVES: This 24-month, double-blind, split-mouth randomized clinical trial aimed to compare the retention rates of a preheated thermoviscous composite resin (PHT) compared to a non-heated composite resin (NHT) in non-carious cervical lesions (NCCLs). METHODS: A total of 120 restorations were restored on NCCLs using a preheated (VisCalor bulk, Voco GmbH) and a non-heated (Admira Fusion, Voco GmbH) composite resins with 60 restorations per group. A universal adhesive in the selective enamel conditioning was applied. In the PHT group, composite was heated at 68 °C for using a bench heater. In the NHT group, no heating was employed. Both restorative materials were dispensed into caps and inserted into the NCCLs. The restorations were evaluated at baseline, 6, 12, 18, and after 24 months of clinical service using the FDI criteria. Statistical analysis was performed with Kaplan-Meier estimation analysis for retention/fracture rate and Chi-square test for the other FDI parameters (α=0.05). RESULTS: After 24 months 108 restorations were assessed. Seven restorations were lost (two for PHT group and five for NHT group), and the retention rates (95 % confidence interval [CI]) were 96.7 % (81.5-99.9) for PHT group and 90.8 % (81.1-96.0) for NHT group, with no statistical differences between them (p > 0.05). The hazard ratio (95 % CI) was 0.52 (0.27 to 1.01), with no significant difference within groups. In terms of all other FDI parameters that were assessed, all restorations were deemed clinically acceptable. CONCLUSIONS: Both composites showed high rates of retention rates after 24 months. CLINICAL SIGNIFICANCE: The clinical performance of the new preheated thermoviscous was found to be as good as the non-heated composite after 24-month of clinical evaluation in non-carious cervical lesions. REGISTRATION OF CLINICAL TRIALS: RBR-6d6gxxz.

6.
Dent Mater ; 40(4): 619-628, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38369403

RESUMO

OBJECTIVES: To evaluate the clinical performance of posterior restorations over wet and dry dentin with an etch-and-rinse adhesive after 36 months of clinical service. METHODS: Forty-five participants were recruited, each one had at least two posterior teeth that needed restoration. Ninety restorations were placed on Class I or Class II cavities. For the restoration protocol, a simplified etch-and-rinse adhesive (Adper Single Bond 2) was applied over wet (WD) or dry dentin (DD) and later restored with a bulk-fill composite (Filtek Bulk Fill) under rubber dam isolation. Each restoration was evaluated using the World Dental Federation (FDI) criteria after 6, 12, and 36 months of clinical service, regarding the following principal restoration characteristics: postoperative sensitivity, marginal discoloration, marginal adaptation, fracture of material and retention, and recurrence of caries. Kruskal Wallis analysis of variance rank (α = 0.05) and Kaplan-Meier survival analysis were used for statistical analysis. RESULTS: After 36 months of clinical evaluation, no significant difference between groups was observed in each FDI criterion (p > 0.05). Twenty restorations (WD=10, DD=10) showed minor marginal staining, and twenty-two restorations (WD=11, DD=11) presented small marginal adaptation defects (p > 0.05). Four restorations were lost (WD = 2, DD = 2) and the fracture rates (95% confidence interval) were 94.9% for each one, without significant difference between wet and dry dentin (p > 0.05). SIGNIFICANCE: The degree of dentin moisture does not seem to affect the clinical performance of a simplified etch-and-rinse adhesive in posterior restorations when the adhesive is applied vigorously over the dentine surface.


Assuntos
Cárie Dentária , Cimentos Dentários , Humanos , Adesivos Dentinários/química , Cimentos de Resina , Restauração Dentária Permanente/métodos , Resinas Compostas/química , Cárie Dentária/terapia , Dentina , Adaptação Marginal Dentária
7.
Clin Oral Investig ; 28(3): 171, 2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38400920

RESUMO

OBJECTIVES: This study aims to assess hydrogen peroxide (HP) penetration within the pulp chamber, color change (CC), physical-chemical properties, and temperature using in-office different concentration bleaching gels with or without violet light. MATERIALS AND METHODS: Fifty teeth were divided into five groups (n = 10) based on the HP concentration bleaching gels used (6% and 35%) and the used violet light (with or without). HP penetration within the pulp chamber was measured using UV-Vis. The CC was evaluated with a digital spectrophotometer. Initial and final concentration, and pH were measured through titration, and a Digital pHmeter, respectively. Temperature analyses were measured through a thermocouple. Statistical analysis included two-way ANOVA, Tukey's, and Dunnett's test (α = 0.05). RESULTS: The presence of violet light did not affect the amount of HP within the pulp chamber, or the CC (p > 0.05). Greater penetration of HP was observed within the pulp chamber, as well as CC when using 35% HP (p < 0.05). The final concentration of both gels was lower than the initial concentration, regardless of the use of violet light (p < 0.05). The initial and final pH levels remained neutral and stable (p > 0.05). The pulp temperature increased when the gels were used in conjunction with violet light (p < 0.05). CONCLUSIONS: Using violet light in conjunction with 6% or 35% HP does not alter the physical properties of the bleaching agents, the penetration of HP or enhance color change. However, an increase in temperature was observed when violet light was applied associated with bleaching gels. CLINICAL RELEVANCE: While the simultaneous use of violet light with hydrogen peroxide 6% or 35% does not alter the material's properties, it also does not bring benefits in reducing hydrogen peroxide penetration and improving color change. Furthermore, the use of violet light increases pulp temperature.


Assuntos
Clareadores Dentários , Clareamento Dental , Peróxido de Hidrogênio , Peróxidos , Ácido Hipocloroso , Géis
8.
J Esthet Restor Dent ; 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353378

RESUMO

OBJECTIVE: Assess color alteration and hydrogen peroxide (HP) penetration in human and bovine teeth using various in-office bleaching protocols with different application times. MATERIALS AND METHODS: Thirty healthy human premolars and 30 healthy bovine incisors were divided into five groups and subjected to different bleaching protocols: 2 × 15 min, 1 × 30 min, 2 × 20 min, or 1 × 40 min, with a control group for each tooth type. All teeth were treated with 35% HP gel. Color alteration was measured using digital spectrophotometry before and 1 week after bleaching. HP concentration within the pulp was determined via UV-Vis spectrophotometry. Statistical analysis included one-way ANOVA, Tukey's, and Dunnett's tests (α = 0.05). RESULTS: All groups exhibited significant color alteration, with no statistically differences among them (p > 0.05). However, significant differences were observed when compared with their respective control groups (p < 0.05). HP penetration into the pulp was evident in all bleached teeth compared to the control groups (p < 0.05), with the 2 × 20 group showing the highest HP levels within the pulp cavity, irrespective of tooth type (p < 0.05). CONCLUSION: A simplified 1 × 30-min protocol can be recommended as it effectively maintains color alteration and HP penetration, irrespective of whether human or bovine teeth. CLINICAL SIGNIFICANCE: This study suggests that an in-office dental bleaching protocol using a 1 × 30-min session is recommended, as it ensures both effective color change and no increase in the amount of HP penetration.

9.
J Esthet Restor Dent ; 36(2): 402-409, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37681984

RESUMO

OBJECTIVE: To evaluate the penetration of hydrogen peroxide (HP) into the pulp chamber and the color change of different bleaching varnishes in low concentrations used for at-home bleaching. MATERIALS AND METHODS: Ninety healthy premolars were used, randomly distributed into nine groups (n = 10) according to bleaching varnish (PL, PolaLuminate; VS, VivaStyle Paint On Plus; CA, Cavex Bite&White whitening pen and; AW AlignerWhite) and time (10 and 30 min), and a control group (no bleaching). The penetration of HP was evaluated by UV-Vis spectroscopy. To evaluate the color change (ΔEab , ΔE00 , ΔWID ) a digital spectrophotometer was used (α = 0.05). RESULTS: The AW group in 10 min and the control group showed similar and lower HP penetration in the pulp chamber when compared to the other groups (p = 0.003). Increasing the application time to 30 minutes elevated the amount of HP inside the pulp chamber for all groups (p = 0.003), except for PL (p > 0.05). When applied for 30 min all bleaching varnishes showed higher color change (ΔWID ) when compared to 10 min (p = 0.04). CONCLUSIONS: For all bleaching varnishes evaluated, PolaLuminate applied for 30 min showed lower penetration into the pulp chamber and higher bleaching effects. CLINICAL SIGNIFICANCE: The use of bleaching varnishes seems promising for teeth bleaching, but it varies according to user product and protocol.


Assuntos
Clareadores Dentários , Clareamento Dental , Peróxido de Hidrogênio/farmacologia , Cavidade Pulpar , Clareamento Dental/métodos , Clareadores Dentários/farmacologia , Espectrofotometria , Cor
10.
J Esthet Restor Dent ; 36(3): 460-468, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37728145

RESUMO

OBJECTIVE: This study aims to assess hydrogen peroxide (HP) penetration into the pulp chamber, color change (CC), physical-chemical properties, and material wastage (MW) and material used (MU) in mixing tips when using in-office bleaching gels with two different mixing tips. MATERIALS AND METHODS: Forty teeth were divided into five groups (n = 8) based on the bleaching gels used (Pola Office +37.5% [PO+] and Whiteness HP Automixx Plus 35% [AM+]) and the mixing tip types (T-Mixer and Helical). A negative control group was treated with ultra-purified water. HP concentration was measured using UV-Vis, and CC was evaluated with a digital spectrophotometer. Initial concentration, pH, and viscosity were measured through Titration, a Digital pH meter, and Rheometer, respectively. MW and MU were measured using a precise analytical balance. Statistical analysis included two-way ANOVA, Tukey's, and Dunnett's test (α = 0.05). RESULTS: A higher HP concentration was observed with PO+ with the Helical mixing tip in comparison with AM+ (p = 0.01). No significant differences in CC or MU were found for different mixing tips (p = 0.001). The T-mixer mixing tip resulted in significantly less MW (p < 0.00001) and improved mixture homogeneity and viscosity. CONCLUSIONS: Utilizing a T-mixer with self-mixing bleaching gels achieves comparable CC while reducing MW. Moreover, it decreases HP penetration when using PO+. CLINICAL SIGNIFICANCE: For the application of a self-mixing in-office bleaching gel, a T-mixer mixing tip should be recommended, as it reduces the penetration of hydrogen peroxide into the pulp chamber when using PO+, while also minimizing gel wastage.


Assuntos
Clareadores Dentários , Clareamento Dental , Peróxido de Hidrogênio , Clareamento Dental/métodos , Esmalte Dentário , Géis , Cor
11.
J Dent ; 142: 104823, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38145806

RESUMO

OBJECTIVE: To evaluate the effect of prolonged (P) polymerization time of a universal adhesive system applied in etch-and-rinse (ER) or self-etch (SE) strategies on the clinical performance of restorations in non-carious cervical lesions (NCCLs), after 36 months of clinical service. METHODS: A total of 140 restorations were randomly placed in 35 subjects according to the polymerization time groups: ER (10 s); ER-P (40 s); SE (10 s); and SE-P (40 s) at 1,200 mW/cm2. Composite resin was placed incrementally. The restorations were evaluated immediately and after 6, 12, 18, and 36 months using the FDI criteria. Data were analyzed using the Kaplan-Meier survival test for retention loss, and the Kruskal-Wallis' test for secondary outcomes (α = 0.05). RESULTS: After 36 months, 19 restorations were lost: ER 6, ER-P 2, SE 9, SE-P 2. The retention rates were 82.3% for ER; 94.1 % for ER-P; 73.5 % for SE; and 94.1 % for SE-P, with a significant difference between ER vs. ER-P and SE vs. SE-P, as well as ER vs. SE-P and ER-P vs. SE (p < 0.0001). Minor defects were observed in 18 restorations for the marginal staining criteria: ER 5, ER-P 2, SE 8, SE-P 3; and in 33 restorations for the marginal adaptation criteria: ER 11, ER-P 4, SE 12, and SE-P 6 (p > 0.05). No restorations showed recurrence of caries or postoperative sensitivity. CONCLUSIONS: A prolonged polymerization time of 40 s improves the clinical performance of the universal adhesive for both adhesive strategies evaluated, even after 36 months. CLINICAL SIGNIFICANCE: Prolonging the polymerization time of a universal adhesive from 10 to 40 s has been shown to improve its clinical performance when used in NCCLs.


Assuntos
Cimentos Dentários , Adesivos Dentinários , Humanos , Resinas Compostas/uso terapêutico , Adaptação Marginal Dentária , Falha de Restauração Dentária , Restauração Dentária Permanente , Adesivos Dentinários/uso terapêutico , Polimerização , Cimentos de Resina/uso terapêutico , Colo do Dente/patologia , Método Duplo-Cego
12.
Dent Mater ; 40(3): 466-476, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38142146

RESUMO

OBJECTIVES: The aim of this study was to evaluate the clinical performance of surface sealants associated with a bulk-fill composite in posterior restorations after 4 years. METHODS: A total of 174 posterior restorations were performed on 57 participants using a self-etch adhesive system and a bulk-fill composite. The groups were then divided into the following categories: 1) without surface sealant (NoS), 2) with surface sealant Biscover (Bisco, SBi), and 3) with surface sealant Permaseal (Ultradent, SPe). Restorations were evaluated using FDI criteria at baseline and after 1 and 4 years. Statistical analysis was conducted using Kaplan-Meier survival analysis and the Chi-square test (α = 0.05). RESULTS: After 4 years, only one restoration was lost (1 in the NoS group). The fracture/retention rate (with 95% confidence interval) was 98% for NoS and 100% for both SBi and SPe (p = 0.76). The majority of secondary outcomes showed minor defects, with no significant differences among the groups (p > 0.05). However, significant differences were observed among the groups in terms of marginal staining and marginal adaptation (p = 0.03). In both items, twelve restorations (nine in NoS, one in SBi, and two in SPe) showed minor marginal discrepancies favoring the sealant groups (SBi and SPe). SIGNIFICANCE: Regardless of the use of surface sealants, the bulk-fill composite restorations showed excellent clinical performance after 4 years. However, the groups that received sealants showed better marginal adaptation and less marginal discoloration compared to those that did not receive sealants.


Assuntos
Resinas Compostas , Cárie Dentária , Humanos , Restauração Dentária Permanente , Adaptação Marginal Dentária , Materiais Dentários , Projetos de Pesquisa
13.
Restor Dent Endod ; 48(4): e33, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38053778

RESUMO

Objectives: This study aimed to evaluate the bleaching efficacy and hydrogen peroxide permeability in the pulp chamber by the at-home bleaching gel in protocols applied on different dental surfaces. Materials and Methods: Forty premolars were randomly into 4 groups: control group no bleaching, only application on the buccal surface (OB), only application on the lingual surface (OL) and application in buccal and lingual surfaces, simultaneously (BL). At-home bleaching gel (White Class 7.5%) was used for the procedure. The bleaching efficacy was evaluated with a digital spectrophotometer (color change in CIELAB [ΔE ab] and CIEDE 2000 [ΔE 00] systems and Whitening Index for Dentistry [ΔWID]). The hydrogen peroxide permeability in the pulp chamber (µg/mL) was assessed using UV-Vis spectrophotometry and data were analyzed for a 1-way analysis of variance and Tukey's test (α = 0.05). Results: All groups submitted to bleaching procedure showed bleaching efficacy when measured with ΔE ab and ΔE 00 (p > 0.05). Therefore, when analyzed by ΔWID, a higher bleaching efficacy were observed for the application on the groups OB and BL (p = 0.00003). Similar hydrogen peroxide permeability was found in the pulp chambers of the teeth undergoing different protocols (p > 0.05). Conclusions: The application of bleaching gel exclusively on the OB is sufficient to achieve bleaching efficacy, when compared to BL. Although the OL protocol demonstrated lower bleaching efficacy based on the ΔWID values, it may still be of interest and relevant in certain clinical scenarios based on individual needs, requiring clinical trials to better understand its specificities.

14.
J Adhes Dent ; 25(1): 257-266, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-38116811

RESUMO

PURPOSE: This study evaluated the long-term push-out bond strength (PBS) and nanoleakage (NL) of universal adhesives with different photo-initiator systems in the root canals of teeth in which fiber posts were luted. MATERIALS AND METHODS: One-hundred twenty endodontically treated human premolars were randomly divided into 12 groups based on the following factors: adhesives (Scotchbond Universal [SBU], Ambar Universal [AMB], and Ambar Universal APS [AMB-APS]); adhesive strategy (etch-and-rinse and self-etch), and time of testing (immediately vs after 2 years). The posts were cemented, sectioned into slices, tested for PBS at 0.5 mm/min, and examined for NL using scanning electron microscopy immediately thereafter or after 2 years of water storage. Data were evaluated using a four-way ANOVA (root thirds vs time vs universal adhesive vs adhesive strategies) and Tukey's test (α = 5%). RESULTS: For both evaluation times, AMB-APS demonstrated no significant difference in the PBS or NL when different radicular thirds were compared (p > 0.05). However, for SBU and AMB, the cervical third demonstrated higher PBS and lower NL than those of the apical third at both time points (p < 0.0001). AMB-APS exhibited higher PBS and lower NL in the apical third in comparison with SBU and AMB (p < 0.0001). SBU and AMB displayed a significant decrease in the PBS and increased NL after 2 years (p < 0.0001), whereas AMB-APS demonstrated no significant signs of degradation even after 2 years of water storage (p > 0.05). CONCLUSION: Independent of the root third evaluated, the universal adhesive containing APS photo-initiator system demonstrated bonding stability at the adhesive interface between the root canal and fiber posts, even after 2 years of water storage.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Humanos , Cimentos Dentários/química , Metacrilatos/química , Cimentos de Resina/química , Água , Dentina , Colagem Dentária/métodos , Teste de Materiais , Adesivos Dentinários/química , Adesivos
15.
Braz Dent J ; 34(5): 87-94, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38133477

RESUMO

This study aimed to evaluate the effects of the application of 10% sodium ascorbate (SA) after in-office bleaching on the penetration of hydrogen peroxide (HP) into the pulp chamber, color change, and microtensile bond strength (µTBS) to the resin-enamel interface. Thirty premolars and thirty molars were randomly divided into three groups (n = 20 each). One group was exposed to deionized water (negative control). The other two groups were bleached with 35% HP in a single session for 3x15 minutes for each application. However, in only one of them, SA was applied for 10 minutes after bleaching. After, the concentration (µg/mL) of HP in each pulp chamber was evaluated by UV-Vis spectrophotometry. Color changes (ΔEab, ΔE00, and ΔWID) were evaluated with a digital spectrophotometer before and in the first week after bleaching. After treatment, molars were restored and sectioned to obtain resin-enamel interface sticks for µTBS at a crosshead speed of 1 mm/min until failure. The HP concentration and µTBS data were analyzed using one-way ANOVA and Tukey tests, and color changes were analyzed by t-tests (α = 0.05). SA application significantly improved the µTBS values and reduced the HP concentrations within the pulp chambers (p < 0.0001). The application of SA significantly interfered with the color changes after bleaching when compared to the control group (p < 0.05). Application of 10% SA after in-office bleaching successfully reduced the penetration of HP into the pulp chamber; however, it decreased color change.


Assuntos
Clareadores Dentários , Clareamento Dental , Peróxido de Hidrogênio/química , Ácido Ascórbico/farmacologia , Cavidade Pulpar , Esmalte Dentário , Clareadores Dentários/farmacologia
16.
Int J Dent ; 2023: 4625818, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37954498

RESUMO

Introduction: Dental bleaching is the first choice to improve smile esthetics, but, in some cases, it needs to be associated with resin composite restoration to obtain a satisfactory result. Unfortunately, the bonding of resin-based materials can be impaired due to residual oxygen molecules, which can decrease the durability of the restoration. Objectives: To evaluate the effect of the antioxidant application on the bond strength of bleached enamel after 24 hr and 3 years of water storage. Methods: In total, 84 bovine teeth were used in this study. Of these, 77 were bleached with 35% hydrogen peroxide in a single session for three cycles of 15 min. Then, the specimens were divided into groups (n = 7 each): control (without bleaching), without antioxidant (WA) use; application of 10% sodium ascorbate (SA) gel, grape seed (GS) extract, and aloe vera (AV). The restorative procedure was performed immediately after bleaching, 7 and 14 days after bleaching. Specimens were sectioned and evaluated using microtensile bond strength (µTBS). Half of the resin-enamel sticks were tested after 24 hr, and the remaining half after 3 years of water storage. µTBS data were analyzed using a three-way analysis of variance, Tukey's test, and Dunnett's test. Results: The lowest µTBS values were observed when the restoration was performed immediately after bleaching in the AV, GS, and WA groups when compared with the SA group (p < 0.005). However, no significant differences were observed among all groups after 3 years of water storage (p < 0.001). Conclusions: SA at 10% was the most effective antioxidant agent for improving the immediate bond strength. However, independent of the antioxidant agent used, the bond strength values were maintained or recovered after 3 years of water storage. SA at 10% could be used to avoid delayed bonding procedures after in-office whitening without compromising bond strength over time. Clinical Significance. The use of antioxidants after dental bleaching can be effective in improving the bonding durability of the adhesive restorations.

17.
Dent Mater ; 39(12): 1159-1168, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37839995

RESUMO

OBJECTIVES: The aim of this double-blind, and randomized controlled clinical trial was to evaluate the 5-year clinical performance of posterior resin composite restorations placed with the incremental filling technique [IF] or the bulk-fill technique [BF]. Two different adhesive systems were used: etch-&-rinse (ER) or self-etch (SE). METHODS: Posterior dental teeth of 72 participants (n = 236), with a cavity depth of at least 3 mm, were randomly divided into four groups. Restorations were applied with either Tetric N-Bond or Tetric N-Bond SE. The composite resin Tetric N-Ceram Bulk-Fill was placed either with IF or BF. Restorations were evaluated using FDI criteria at baseline and after 1, 2, 3, 4, and 5 years. Statistical analysis was performed using the Wilcoxon Signed rank test (a=0.05). RESULTS: Two hundred and four restorations were evaluated after 5 years. Eleven restorations were considered 'failed', ten due to fracture (4 IF and 6 BF) and one due to secondary caries (IF). The annual failure rate was 1.2% for BF and 1% for IF (p = 0.35). When comparing BF and IF, no significant differences were found for any of the parameters evaluated (p > 0.05). Regarding the adhesive systems, 44 and 51 restorations showed minor problems in terms of marginal adaptation and staining, with significantly more marginal discoloration when the self-etch adhesive was used (p = 0.002). SIGNIFICANCE: The bulk-fill restorative technique showed good clinical behavior compared to the incremental filling technique, especially when using an etch-&-rinse adhesive, after 5 years of clinical evaluation.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Humanos , Restauração Dentária Permanente/métodos , Resinas Compostas/química , Método Duplo-Cego , Cimentos de Resina , Adaptação Marginal Dentária
18.
Dent Mater ; 39(11): 1051-1057, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37793951

RESUMO

OBJECTIVE: To evaluate the effect of dimethyl sulfoxide (DMSO) on the microtensile bond strength (µTBS) and nanoleakage (NL) of universal adhesives on eroded dentine, immediately and after four years of water storage. METHODS: Sixty-four sound human molars were distributed into 16 groups according to (1) Dentine surface (sound and eroded dentine); (2) dimethyl sulfoxide application (with or without); (3) Application mode (etch-and-rinse or self-etch) and (4) Storage time (immediate and four years). One mild universal adhesive was used (Scotchbond Universal). The restoration was then performed with a composite resin and the specimens were sectioned into resin-dentine bonded sticks. Resin-dentine bonded sticks were tested (immediately and after four years of water storage) for µTBS (0.5 mm/min) or used to assess NL. Data on µTBS and NL were analyzed using four-way ANOVA and Tukey's test (α = 0.05). RESULTS: Only the 3-way cross-product interaction 'substrate vs DMSO vs time' was statistically significant (p = 0.007). Eroded dentine showed a lower mean of µTBS and a higher mean of NL values than sound dentine. However, when DMSO was applied, no significant decrease of µTBS or NL values was observed after four years of water storage, regardless of adhesive strategies, or dentine evaluated, when compared to immediate results. SIGNIFICANCE: Water-based DMSO pre-treatments not only prevent degradation of MDP-containing simplified adhesives but also serve as a potential alternative to improve long-term bonding properties to eroded dentine. The versatility of using a single pre-treatment for both self-etch or etch-and-rinse bonding to eroded dentin may facilitate future clinical applications.


Assuntos
Colagem Dentária , Dimetil Sulfóxido , Humanos , Cimentos Dentários , Colagem Dentária/métodos , Adesivos Dentinários/química , Condicionamento Ácido do Dente/métodos , Cimentos de Resina/química , Dentina , Água/química , Resistência à Tração , Teste de Materiais
19.
Braz. dent. j ; 34(5): 87-94, Sept.-Oct. 2023. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1528015

RESUMO

Abstract This study aimed to evaluate the effects of the application of 10% sodium ascorbate (SA) after in-office bleaching on the penetration of hydrogen peroxide (HP) into the pulp chamber, color change, and microtensile bond strength (µTBS) to the resin-enamel interface. Thirty premolars and thirty molars were randomly divided into three groups (n = 20 each). One group was exposed to deionized water (negative control). The other two groups were bleached with 35% HP in a single session for 3x15 minutes for each application. However, in only one of them, SA was applied for 10 minutes after bleaching. After, the concentration (µg/mL) of HP in each pulp chamber was evaluated by UV-Vis spectrophotometry. Color changes (ΔEab, ΔE00, and ΔWID) were evaluated with a digital spectrophotometer before and in the first week after bleaching. After treatment, molars were restored and sectioned to obtain resin-enamel interface sticks for µTBS at a crosshead speed of 1 mm/min until failure. The HP concentration and µTBS data were analyzed using one-way ANOVA and Tukey tests, and color changes were analyzed by t-tests (α = 0.05). SA application significantly improved the µTBS values and reduced the HP concentrations within the pulp chambers (p < 0.0001). The application of SA significantly interfered with the color changes after bleaching when compared to the control group (p < 0.05). Application of 10% SA after in-office bleaching successfully reduced the penetration of HP into the pulp chamber; however, it decreased color change.


Resumo Este estudo teve como objetivo avaliar os efeitos da aplicação do ascorbato de sódio a 10% (AS) depois do clareamento em consultório na penetração do peróxido do hidrogênio (PH) na câmara pulpar, mudança de cor e resistência de união (RU) da interface resina-esmalte. Trinta pré-molares e trinta molares foram divididos aleatoriamente em três grupos (n = 20). Um grupo foi exposto em água deionizada (controle negativo). Os outros dois grupos foram clareados com 35% PH numa única sessão de 3x15 minutos para cada aplicação. Porém, só um grupo recebeu AS durante 10 minutos depois do clareamento. Depois, a concentração (µg/mL) do PH no interior de cada câmara pulpar foi avaliado com espectrofotometria UV-Vis. A mudança de cor (ΔEab, ΔE00 and ΔWID) foi avaliada como espectrofotômetro digital antes e depois de uma semana do clareamento. Após de cada tratamento, os molares foram restaurados e seccionados em espécimes com interface resina-esmalte para o teste de RU por microtração a uma velocidade de 1 mm/min até a fratura. Os dados da concentração de PH e RU foram analisados usando ANOVA de uma via e teste de Tukey, e a mudança de cor com o teste t (α = 0.05). A aplicação de AS melhorou significativamente a RU e reduziu a concentração de PH na câmara pulpar (p < 0.0001). A aplicação de AS interferiu significativamente na mudança de cor depois do clareamento comprado com o grupo controle (p < 0.05). A aplicação de SA a 10% depois do clareamento em consultório reduziu significativamente a penetração do PH na câmara pulpar e interferiu na mudança de cor.

20.
Dent Mater ; 39(10): 946-956, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37648563

RESUMO

OBJECTIVES: To evaluate the influence of a glutaraldehyde-based desensitizer (GL) on postoperative sensitivity (POS) in posterior bulk-fill resin composite restorations using an adhesive applied in the self-etch (SE) and etch-and-rinse (ER) strategies; and to assess the clinical performance of the restorations. METHODS: Posterior resin composite restorations (n = 228) at least 3 mm deep were inserted in 57 subjects using a split-mouth design. The adhesive was applied with/without prior application of a GL. A resin composite was used for all restorations. Spontaneous POS (risk and intensity), as well as POS caused by stimulation with an air blast and assess the response to horizontal and vertical percussion was assessed using two scales in the baseline and after 7, 14, and 30 days. In addition, some parameters were evaluated using FDI criteria up to 24 months of clinical service. RESULTS: No significant POS was observed (p > 0.05). A higher absolute risk and intensity of spontaneous POS was observed within 7 days (35.1%), without statistically significant differences among groups. At 24 months 5 restorations were considered clinically unsatisfactory, and 73 restorations showed minor discrepancies in adaptation, with no significant differences between groups (p > 0.05). SIGNIFICANCE: A GL agent does not influence POS in posterior restorations with bulk-fill resin composite. It may be considered a dispensable clinical step in the restorative protocol.


Assuntos
Resinas Compostas , Boca , Humanos , Glutaral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...